Specification (millimetre) | Allowable error of unevenness (micron) | |||
| 0级 | 1级 | 2级 | 3级 | |
| 100*200 | 6 | 12 | 24 | |
| 200*200 | 6 | 12 | 24 | |
| 200*300 | 7 | 13 | 25 | |
| 300*300 | 7 | 13 | 26 | |
| 300*400 | 7 | 14 | 28 | |
| 400*400 | 7 | 14 | 28 | |
| 400*600 | 8 | 16 | 35 | 80 |
| 450*600 | 8 | 16 | 32 | 80 |
| 500*600 | 9 | 18 | 36 | 90 |
| 750*1000 | 10 | 20 | 40 | 110 |
| 1000*1500 | 12 | 25 | 50 | 125 |
| 1500*2000 | - | - | 60 | 150 |
| 3000*3000 | 200 | |||
| 3000*5000 | - | - | 200 | |
According to GB/T22095-2008 standard manufacturing products made of plate and box type, the face is rectamgular,material HT200-HT400,face scraping process,special holes and T/V/U shaped grooves can be processed at the face area. The table is used to build a testing or crossed Datum apparatus. The flat-panel installation should be raised to the level of the load being evenly distributed on each fulcrum, the ambient temperature (20±5°C) should be used to avoid vibration.